Heating, Ventilating and Cooling Equipment (HVAC)

ENERGY STAR® Criteria for Qualified HVAC Products
Air conditioners – Central
Air conditioners – Room
Boilers – Oil or Gas (Residential)
Ceiling Fans
Furnaces (Forced-Air) gas, propane, oil
Heat pumps – Air source
Heat pumps – Ground Source
Programmable Thermostats
Ventilating Fans
Water Heaters
Air Conditioners – Central
List of models: Split system air-conditioners
List of models: Split system heat pumps
ENERGY STAR qualified central air conditioning systems are about 8 percent more efficient than standard models. The energy efficiency of this product is measured by a Seasonal Energy Efficiency Ratio (SEER) and an Energy Efficiency Ratio (EER). Typical residential systems are "split" with a separate indoor evaporator unit in the furnace ducting and an outdoor condenser unit. There are also "single package" systems that have the evaporator and condenser in one unit. The following levels must be met or exceeded to qualify for ENERGY STAR:
| Type | SEER | EER |
|---|---|---|
| Split | >= 14.5 | >= 12.0 |
| Single Package | >= 14.0 | >= 11.0 |
Single package units with electric air-conditioning and gas heating cannot qualify for ENERGY STAR in Canada.
Technical specifications for central air conditioners for manufacturers
Air Conditioners – Room
List of models: Room Air Conditioners
EnerGuide Room Air Conditioner Directory
ENERGY STAR qualified room air conditioners use at least 10 percent less energy than conventional models. The following table shows the energy efficiency ratio (EER) requirements for the various styles and cooling capacities. The ENERGY STAR symbol may also appear on the EnerGuide label to show that the unit is ENERGY STAR qualified.
| Style | Btu/hr. |
EER Window-mounted (louvered sides) |
EER Through-the-wall (no louvered sides) |
|---|---|---|---|
| Standard | < 6 000 | >= 10.7 | >= 9.9 |
| 6 000 to 7 999 | >= 10.7 | >= 9.9 | |
| 8 000 to 13 999 | >= 10.8 | >= 9.4 | |
| 14 000 to 19 999 | >= 10.7 | >= 9.4 | |
| >= 20 000 | >= 9.4 | >= 9.4 | |
| Casement-only | N/A | >= 9.6 | N/A |
| Casement-slider | N/A | >= 10.5 | N/A |
Standard style models are designed to fit into a slider or hung type window while through-the-wall models are for installation in a wall opening. Casement-only and casement-slider styles are designed so that they can fit into a casement type window. Note that a special electric plug is required for 240 volt models.
Technical specifications for room air conditioners for manufacturers
Boilers – Residential
List of models: Gas-fired boilers
List of models: Oil-fired boilers
Boilers designed for space heating can also provide domestic hot water for residential applications. There are two basic methods used:
-
Indirect storage. These well-insulated tanks operate as a separate heating zone with substantially reduced heat losses and higher efficiencies as compared to tankless coils.
- Tankless coil. Operating a boiler with a tankless coil will reduce the overall energy efficiency of the boiler.
Technical specifications for residential boilers for manufacturers
Water Heaters
List of models: Gas Water Heaters
List of models: Tankless Water Heaters
ENERGY STAR qualified water heaters use at least 5 percent less energy than conventional models. The energy efficiency performance for water heaters is measured by the Energy Factor (EF). The higher the EF, the more efficient the water heater. There are also requirements for the First-Hour Rating (FHR) of the storage, condensing and heat pump water heaters. The FHR is the amount of hot water in litres a water heater can supply in one hour starting with a full tank. For tankless water heaters, the rating used is Litres per minute (LPM). LPM is the amount of hot water in litres per minute that a tankless water heater can supply over a 42.8 Celcius degree rise. The following types of water heaters must meet or exceed the following EF levels in order to qualify as ENERGY STAR:
| Product Category | Minimum Efficiency Rating | First – Hour Rating |
|---|---|---|
|
Gas storage water heater Until August 31, 2010 |
EF ≥ 0.62 | FHR ≥ 254 litres per hour |
|
Gas storage water heater As of September 1, 2010 |
EF ≥ 0.67 | FHR ≥ 254 litres per hour |
| Gas tankless water heater | EF ≥ 0.82 | LPM ≥ 9.5 over 42.8°C rise |
| Condensing gas storage water heater | EF ≥ 0.80 | FHR ≥ 254 litres per hour |
| Heat pump water heater | EF ≥ 2.0 | FHR ≥ 190 litres per hour |
| Solar water heater | Net solar energy contribution equivalent to ≥ 7.0 GJ/year |
Technical specifications for domestic Water Heaters
Ceiling Fans
ENERGY STAR qualified ceiling fans move air up to 20 percent more efficiently than standard ceiling fans.
| Fan Speed | Minimum Airflow | Efficiency Requirement |
|---|---|---|
| Low | 35.4 m3/min. (1250 cfm) | 4.4 m3/min (155 cfm) per watt |
| Medium | 85.0 m3/min. (3000 cfm) | 2.8 m3/min (100 cfm) per watt |
| High | 141.6 m3/min. (5000 cfm) | 2.1 m3/min (75 cfm) per watt |
If your ENERGY STAR qualified ceiling fan doesn't include lighting and you wish to add it, be sure to purchase an ENERGY STAR qualified light kit. These kits come with either pin-based compact flourescent lamps (CFLs) or screw-based CFLs. This lighting is more efficient than standard incandescent lighting and long lasting, so you won't have to make frequent bulb changes.
Ceiling Fan Tips:
- Fans should be installed with the blades at least 30 cms below the ceiling, 200 cms from the floor and 60 cms from the nearest wall.
- Air should be moved downwards from the ceiling in the summer to provide a cooling breeze on the room occupants.
- If the fan is used in the winter, air should be moved upwards towards the ceiling to disperse the warm air that tends to accumulate there and distribute it more evenly in the room.
- During the summer, switch the fan and light off when you leave the room. Fans don't actually cool a room, they just cool circulate the air.
Technical specifications for ceiling fans for manufacturers
We are currently sharing lists of ENERGY STAR qualified programmable thermostats with ENERGY STAR in the United States. When you click on this link, you will be taken to a product list on the U.S. ENERGY STAR web site. Many of the products listed are available in Canada.
List of models: Ceiling fans (U.S.)
Residential Furnaces (forced-air)
Furnaces – Gas or Propane
List of models: Gas and propane fired furnaces
A gas or propane fired furnace's energy efficiency performance over a heating season is called the Annual Fuel Utilization Efficiency (AFUE). This AFUE is expressed as a percentage. The higher the percentage, the more efficient the furnace.
Some high-efficiency furnaces using a variable-speed direct current (DC) motor to run the air circulation fan, can significantly reduce electricity consumption while providing better heat distribution.
Residential gas or oil furnaces must have an annual fuel utilization efficiency (AFUE) rating of 90 or higher to qualify for the ENERGY STAR mark. Some high-efficiency furnaces using a variable-speed direct current (DC) motor to run the air circulation fan, can significantly reduce electricity consumption while providing better heat distribution.
Technical specifications for gas and propane fired furnaces for manufactures
Choose the Right Condensing Gas Furnace (Fact Sheet) PDF
Furnaces – Oil
List of models: Oil-fired Furnaces
An oil fired furnace's energy efficiency performance over a heating season is called the Seasonal Energy Utilization Efficiency (SEUE). This SEUE is expressed as a percentage. The higher the percentage, the more efficient the furnace. For furnaces with no standing pilot light, the SEUE is equivalent to the Annual Fuel Utilization Efficiency (AFUE).
Residential oil furnaces must have an annual fuel utilization efficiency (AFUE/SEUE) rating of 85% or more to qualify for the ENERGY STAR symbol.
Technical specifications for oil fired furnaces for manufacturers
Heat Pumps – Air Source
List of models: air source heat pumps (split system and single package)
ENERGY STAR qualified air-source heat pumps are about 6 percent more efficient for heating and about 8 percent more efficient for cooling than standard models. The energy efficiency of this product is measured by Seasonal Energy Efficiency Ratio (SEER) and Energy Efficiency Ratio (EER). Typical residential systems are "split" with a separate indoor evaporator unit in the furnace ducting and an outdoor condenser unit. There are also "single package" systems that have the evaporator and condenser in one unit. The following levels must be met or exceeded to qualify for ENERGY STAR:
January 1‚ 2009
| Type | HSPF | SEER | EER |
|---|---|---|---|
| Split | >= 7.1 | >= 14.5 | >= 12.0 |
| Single Package | >= 7.0 | >= 14.0 | >= 11.0 |
HSPF for Region IV is 8.2 for split system and 8.0 for single package. Region IV is used in the United States while in Canada, we use Region V.
HSPF for Region IV is 8.2 for split system and 8.0 for single package. Region IV is used in the United States.
Technical specifications for air-source heat pumps for manufacturers
Heating and Cooling With a Heat Pump (Fact Sheet) PDF
Heat Pumps – Ground-Source
List of models: Ground source heat pumps
Ground-source heat pumps use the thermal energy of the ground or groundwater to provide a source of heating and/or cooling for a home. There are three basic types: 1) closed loop; 2) open loop; and 3) direct expansion. The cooling function is measured by an Energy Efficiency Ratio (EER), and the heating function is measured by a Coefficient of Performance (COP). The higher the EER or COP number, the more efficient the heat pump is. ENERGY STAR qualified ground-source heat pumps must meet or exceed the following EER and COP levels:
| Product Type | EER | COP |
|---|---|---|
| Water-to-Air | ||
| Closed Loop Water-to-Air | 16.1 | 3.5 |
| Open Loop Water-to-Air | 18.2 | 3.8 |
| Water-to-Water | ||
| Closed Loop Water-to-Water | 15.1 | 3.0 |
| Open Loop Water-to-Water | 19.1 | 3.4 |
| DGX | ||
| Direct Expansion | 16.0 | 3.6 |
Technical specifications for ground source heat pumps for manufacturers
Programmable Thermostats
Natural Resources Canada (NRCan) suspended the ENERGY STAR specification for programmable thermostats effective December 31, 2009. NRCan and the Environmental Protection Agency are currently working on the development of a new specification for climate controls that will replace the current specification. Please continue to consult our website for information on when this specification will come into effect.
Ventilating Fans
ENERGY STAR qualified ventilating fans use, on average, 65 percent less energy than standard models. Because of better blade design, they move more air with less noise and their high performance motors last longer.
Ventilating fans include:
- range hoods
- bathroom fans
- utility fans
- in-line fans
If the fan contains a light fixture, the total lamp wattage must not exceed 50 Watts. The use of compact fluorescent lights (CFLs) is recommended. Fans with a "nightlight" must have a light bulb that consumes 4 watts or less. A minimum of a one year warranty is required. Qualifying ventilating fans may also have sensors, heaters, and timers.
| Product | Airflow |
Minimum Efficacy Level |
Maximum Sones* |
|---|---|---|---|
| Range Hoods |
Up to 14.2 m3/min (500 cfm) |
0.08 m3/min (2.8 cfm) per watt |
2.0 |
|
Bathroom and Utility Room Fans |
.3 to 2.3 m3/min (10 to 80 cfm) |
0.04 m3/min (1.4 cfm) per watt |
2.0 |
|
Bathroom and Utility Room Fans |
2.5 to 3.7 m3/min (90 to 130 cfm) |
0.08 m3/min (2.8 cfm) per watt |
2.0 |
|
Bathroom and Utility Room Fans |
4.0 to 14.2 m3/min (140 to 500 cfm) |
0.08 m3/min (2.8 cfm) per watt |
3.0 |
|
In-line Ventilating Fans |
Any |
0.08 m3/min (2.8 cfm) per watt |
Not Applicable |
* a sone is a measure of how loud the fan is when in operation. The lower the number, the quieter the operation.
Technical specifications for ventilating fans for manufacturers
The ENERGY STAR name and the ENERGY STAR symbol are registered trademarks of the United States Environmental Protection Agency and are used with permission.